Welcome to America Supply
Welcome to America Supply
The Jomar AE-7000-24VAC Double Acting electric actuator 24V AC with 7000 Torque features a hard anodized aluminum hosing with external powder coating for severe duty applications with an IP67 (Ingress Protection) O-Ring sealed enclosure.
Also features a position indicator, manual override and a thermally protected induction motor.

Security - Rest assured. Our site is encrypted and we do not store any payment information
Free Shipping - Free delivery on most products unless otherwise stated
Returns - Products are returnable if unused or defective. Need to call for an RMA authorization
Please Note: Each actuator must be powered through its own individual limit switch or relay contacts to prevent cross feed between two or more actuators. Not doing so will cause damage to the actuators and impact your process control as well as void warranty.
Actuator AE-7000-24VAC Features
- Hard Anodized Aluminum Housing with External Powder Coating for Severe Duty Applications
- 90˚ Operation
- Enclosure: IP67 (Nema 4, 4X) O-Ring Sealed
- ISO 5211 mounting: F07 / F10
- Position indicator
- Adjustable mechanical stops to prevent over travel
- Thermally protected induction motor
- De-clutchable Standard Manual Override
- Temperature Range -4° F to 158° F (-29° to 70° C)
- IEC Duty Cycle (S2) Max 30 minutes
- 2 Limit Switches - 1 each for Open & Close (10A,250VAC)
- 2 Auxiliary Limit Switches - 1 each for Open & Close (10A,250VAC)
- Cable Entry: 2 - 3/4" NPT
- Double worm gearing, no break required
- Spring loaded terminal block for ease in wiring
Certifications (Applies to models CSA applies to models AE-880 – AE9700)
- C22.2 No. 139-1982, 77-95, 100-04, UL429, UL2111, UL1004, 0-M91, 94.1-07, 94:2-07, 30-M1986, 25-1966, 1399-1982, 60529:05, 60079-0-07, 60079-1-07, ANSI/UL 429, 50E, 50, 1002, IEC 60529, 60079-0, 60079-1, and ANSI/UL 1203.
Model AE-1400 AE-2100 AE-3100 AE-4400 AE-7000 AE-9700 Working Torque (in lbs.) 1400 2100 3100 4400 7000 9700 Pattern ISO 5211 F07 / F10 F07 / F10 F10 / F12 F10 / F12 F12 / F14 F12 / F14 Output Square .87 .87 1.06 1.06 1.42 1.42 IEC Duty Cycle (S2) Max 30 minutes Max 30 minutes Max 30 minutes Max 20 minutes Max 20 minutes Max 20 minutes IEC Duty Cycle (S4) 50% 50% 50% 30% 25% 25% Operating Time 90° @ 24VAC (secs) 33 33 37 34 47 94 Rated current @ 24VAC (Amp.) (Running/Max) 2.5/2.7 2.5/2.7 7.8/41 8.25/66 8.25/66 8.25/66 Weight (lbs.) 33 33 44 44 55 55 Limit Switches 2 each for Open and Close (SPDT 250VAC/10A rating) Auxiliary Limit Switches 2 each for Open and Close (SPDT 250VAC/10A rating) Cable Entry 2 - 3/4" NPT Motor Insulation class F Internal Heater Yes - 5W Working Temperature -4° F to 158° F (-29° to 70° C) Torque OPL Protection 1 each for Open and Close (SPDT 250VAC/10A rating) Jomar AE-1400 to AE-9700 24VAC Specs
Jomar AE-1400-9700-24VACNo customer reviews for the moment.